pH Neutral vs. Alkaline Cleaning Agents
Analysis Lab
Ultrasonic Cleaning Causing Damage
Ask the Experts
Removing Flux from Low Standoff Heights
Production Floor
Organic Flux Residue Concerns
Ask the Experts
Is Baking Required After Water Cleaning?
Board Talk
How Clean is Clean?
Production Floor
Cleaning No-Clean Solder Paste
Ask the Experts
Collaborative Cleaning Process Innovations
Production Floor
Why Switch From Pure DI-Water to Chemistry
Production Floor
Effects of Ultrasonic Cleaning
Ask the Experts
More Related Programs  »



Solderability Problems at Low Humidity
Can very low humidity effect solderability of PCB assemblies. Are there other ...
Cleaning Reballed BGA Components
We currently clean reballed BGA components using an ultrasonic cleaner followed by ...
Shelf Life Before Conformal Coating
Prior to conformal coating, how long can we keep a circuit board ...
Solder Paste and the 5 Ball Rule
For either Type III or Type IV solder paste, should there be ...
The Demise of the Plated-Through Hole?
How long do you expect the industry will continue to use through ...
Problems With Wave Solder Lead Bridging
We are wave soldering very close pitch through-hole components and see bridging. ...
Removal of Oxidation from Bare PCBs
What would be the best method or product for cleaning bare PCBs ...
Is Baking Required After Water Cleaning?
Do circuit board assemblies need to be baked after routine aqueous cleaning? ...
Poor Wetting On OSP Coated PCBs
We are experiencing poor wetting on one OSP coated PCB using a ...
What is the Shelf Life of Solder Paste?
What is the practical shelf life of a syringe of solder paste, ...
More Board Talk  »
New High-speed Modular Chip-shooter
New High-speed Modular Chip-shooter
The FX3 is a new high-speed modular chip-shooter delivering cutting edge technology combining speed, performance and high-uptime.
Juki Automation Systems

Staging Time Between Soldering and Cleaning
Staging Time Between Soldering and Cleaning
What is the maximum staging time permissible for PCBA's between wave soldering and cleaning? Is there an industry standard?
This program first published August 2009
Board Talk programs are presented by:

Phil Zarrow
Phil Zarrow, ITM Consulting
With over 35 years experience in PCB assembly, Phil is one of the leading experts in SMT process failure analysis. He has vast experience in SMT equipment, materials and processes.

Jim Hall
Jim Hall, ITM Consulting
A Lean Six-Sigma Master Blackbelt, Jim has a wealth of knowledge in soldering, thermal technology, equipment and process basics. He is a pioneer in the science of reflow.
Comments  »
Use the form below to submit a comment.
You definitely want to wait until the post wave/reflow board temperature is below the temperature of the first wash stage. This will prevent porous components taking on moisture during contraction.

K.D.
C'mon Fellas! Time between soldering and cleaning depends upon more than just the process delays. This has to be considered as a two-part question.

First part is no-cleans. If you're going to clean no-clean fluxes, it depends upon the wash water temperature and the chemistry of the cleaning solution. Saponafiers and other solvents allow you an extended rest period between soldering and wash depending upon the wash temperature and aggressiveness of the cleaning solution. The longer you wait, the harsher and hotter the solution needs to be.

Organic acids on the other hand are a bit more insidious than their no-clean counterparts. The longer they sit, the more corrosion damage they do to the metals on the assembly and the further they creep into porous substrates making them almost impossible to remove completely.

You also forgot to mention that the longer OA's sit, the physically harder the flux gets, changing the chemistry of the wash required to remove the residues. What was once an easy removal in hot DI water becomes a difficult proposition to remove with chemicals, up to the point that they cannot be removed. Did I mention that they stay corrosive even after they harden?

An no mention of cleanliness testing to validate the cleaning process? Omegameter or Ionograph testing will tell you if the boards have been cleaned or if another pass or more aggressive chemistries are required. Ion chromatography is not optimum for routine testing since it is site and ion specific and all you need is a general idea of whether or not the boards meet the specific cleanliness requirements for the assembly.


J.W.
Submit A Comment  »
This comment is about the program:
Staging Time Between Soldering and Cleaning

The is a general comment.
Your Name
Company
E-mail
Country
Comments
Discussion of pricing, recommendations for specific products or advertisements are not appropriate. All comments are reviewed prior to posting. You must include your full name to have your comments posted. We will not post your email address, we request your email address so we can notify you if your comments are posted.
Today's Sponsor
Today's Sponsor
IPC Member Spotlight  »
The Design Process Just Got Easier
The Design Process Just Got Easier
Sunstone Circuits, has released the newest version of their design software, PCB123. Bottom line, the design process just got easier.
Sunstone Circuits
Featured Sponsors  »
Innovative No-clean, Halide-free Tacky Flux
Innovative No-clean, Halide-free Tacky Flux
Multicore TFN700B is a no-clean, halide-free tacky flux formulated to address the challenging requirements of package-on-package applications.
Henkel Corporation
Rigid Flex That is Built to Last
Rigid Flex That is Built to Last
Once you have made the decision to package your electronics with rigid flex, it makes sense to pick a production partner who can build it right.
Printed Circuits, Inc.
Rigid Flex That is Built to Last
Rigid Flex That is Built to Last
Once you have made the decision to package your electronics with rigid flex, it makes sense to pick a production partner who can build it right.
Printed Circuits, Inc.
MSD Damage Causes Early Field Failures
MSD Damage Causes Early Field Failures
Components encapsulated in plastic or organic compounds are susceptible to moisture damage. So are PCBs, all can cause early field failures. Control MSDs per IPC J-Std-033b.1 and 1601.
Super Dry®
A Century of Global Soldering Leadership
A Century of Global Soldering Leadership
Why spend so much time developing profiles for every board, when Vitronics Soltec's Autoset can do it for you, automatically?
Vitronics Soltec
IPC Training & Certification from Blackfox
IPC Training & Certification from Blackfox
Experience the Blackfox difference! Schedule your IPC Training and Certification with Blackfox at one of our many certification sites, or we'll come to you. Find the schedule...
Blackfox Training Institute image
IPC OUTLOOK Logo IPC — Association Connecting Electronics Industries
3000 Lakeside Drive, 309 S, Bannockburn, IL 60015
Phone: 978-478-5112 | Fax: 843-682-4255
Sandy Gentry, Editor | Kim Sterling, Publisher
About IPC Outlook  |  Contact Us  |  Privacy Policy  |  Terms of Use  |  Sponsorships